<?xml version="1.0" encoding="UTF-8" ?>
<modsCollection xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" xmlns:slims="http://slims.web.id" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-3.xsd">
<mods version="3.3" id="-41758">
 <titleInfo>
  <title>Pola aliran dan penurunan tekanan pada aliran dua fase gas-cair melewati pengecilan pipa secara mendadak</title>
 </titleInfo>
 <name type="Personal Name" authority="">
  <namePart>Sumarli</namePart>
  <role>
   <roleTerm type="text">Primary Author</roleTerm>
  </role>
 </name>
 <typeOfResource manuscript="no" collection="yes">mixed material</typeOfResource>
 <genre authority="marcgt">bibliography</genre>
 <originInfo>
  <place>
   <placeTerm type="text"></placeTerm>
  </place>
  <publisher>bag. Serial Teknologi dan Kejuruan : Jurnal Teknologi Kejuruan dan Pengajarannya Fakultas Teknik Universitas Negeri Malang</publisher>
  <dateIssued></dateIssued>
 </originInfo>
 <language>
  <languageTerm type="code">ind</languageTerm>
  <languageTerm type="text">Indonesia</languageTerm>
 </language>
 <physicalDescription>
  <form authority="gmd">Index Artikel</form>
  <extent>Sumber artikel:Jurnal. Halaman: 50-62</extent>
 </physicalDescription>
 <note>The Flow patterns and Pressure Drop on Two-Phase Gas-Liquid Through sudden Contrction. The aim of this research is to describe the flow patterns and ressure drop on two-phase gas-liquid trough sudden contraction. It limits the contraction coefficient (S) into three variants  S 0 8   S  0 6 and S  0 4. For describing the distribition and pressure drop  it uses two-dimension line graphics. The result shows that (1) the flow pattern in horizontal contraction tends to shape separated flow  meanwhile in vertical contraction it tends to shape homogenous inflated flow (2) the pressure on pipe surfaces before contraction surfase is bigger than those of ducting axis  (3) the pressure on pipe surfaces sfter contraction surface is smaller that those of ducting axis  (4) the pressere drop turn into bigger on bigger mass flux and mixtur quality (5) the pressure drop in homogenous flow is bigger than those of separated flow  and (6) the difference average betwen calcuated and theoretical pressure drop is tess than 20%                                  9</note>
 <subject authority="">
  <topic>ALIRAN DUA FASE</topic>
 </subject>
 <classification>690.5 TEK 1 200</classification>
 <identifier type="isbn"></identifier>
 <location>
  <physicalLocation>UPT Perpustakaan UM Koleksi Bahan Pustaka Perpustakaan UM</physicalLocation>
  <shelfLocator>2</shelfLocator>
 </location>
 <slims:digitals>
  <slims:digital_item id="" url="" path="/" mimetype=""></slims:digital_item>
 </slims:digitals>
 <recordInfo>
  <recordIdentifier>-41758</recordIdentifier>
  <recordCreationDate encoding="w3cdtf">2012-01-30 00:00:00</recordCreationDate>
  <recordChangeDate encoding="w3cdtf">2012-01-30 00:00:00</recordChangeDate>
  <recordOrigin>machine generated</recordOrigin>
 </recordInfo>
</mods>
</modsCollection>