

<?xml version="1.0" encoding="UTF-8" ?>
<modsCollection xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" xmlns:slims="http://slims.web.id" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-3.xsd">
<mods version="3.3" id="-94031">
 <titleInfo>
  <title>Deteksi Intensitas Suara Batuk pasien Infeksi Saluran Pernafasan Akut (ISPA) Menggunakan Edge Impulse Machine Learning berbasis Model Mel Frequency Cepstral Coefficients (MFCC)</title>
 </titleInfo>
 <name type="Personal Name" authority="">
  <namePart>Aris Widodo; Muhamad Azwar Annas</namePart>
  <role>
   <roleTerm type="text">Primary Author</roleTerm>
  </role>
 </name>
 <typeOfResource manuscript="no" collection="yes">mixed material</typeOfResource>
 <genre authority="marcgt">bibliography</genre>
 <originInfo>
  <place>
   <placeTerm type="text"></placeTerm>
  </place>
  <publisher>Serial TELKA : Jurnal Telekomunikasi, Elektronika, Komputasi dan Kontrol</publisher>
  <dateIssued></dateIssued>
 </originInfo>
 <language>
  <languageTerm type="code">ind</languageTerm>
  <languageTerm type="text">Indonesia</languageTerm>
 </language>
 <physicalDescription>
  <form authority="gmd">Index Artikel</form>
  <extent>Sumber artikel:Jurnal. Halaman: 12-21</extent>
 </physicalDescription>
 <note>Batuk merupakan salah satu indikator kondisi pasien pengidap penyakit infeksi saluran pernafasan akut (ISPA). Teknologi terkini memiliki banyak metode untuk mendeteksi batuk diantaranya analisis gelombang suara batuk langsung  penggunaan Frequency-Modulated Continuous Wave radar (FMCW) atau jaringan saraf tepi konvolusi dan sebagainya sebagai acuan deteksi suara batuk namun masih belum pada tingkatan pengukuran beruntun dalam bentuk intensitas deteksi batuk tiap waktu. Pada penelitian ini telah dilakukan uji coba alternatif deteksi intensitas menggunakan Mel Frequency Cepstral Coefficients (MFCC) pada platform Edge Impulse untuk mengetahui nilai akurasi deteksi intensitas batuk ISPA. Penelitian ini dilakukan dengan membuat dataset batuk ISPA  membuat pemodelan MFCC pada design Impulse dan pengembangan library mikrokontroler. Library ini diunggah pada mikrokontroler untuk dilakukan uji langsung deteksi batuk beruntun dengan variasi tanpa jeda  jeda 5 detik dan 10 detik dari kompilasi 50 suara batuk. Hasil deteksi diakumulasi dengan nilai confidence level di atas 50% dianggap sebagai batuk dan dihitung nilai akurasi dari rasio jumlah batuk yang terukur. Pada penelitian ini dihasilkan akurasi pengukuran suara batuk tanpa jeda  jeda 5 detik dan 10 detik sebesar 18%  34% dan 62%.       Cough is an indicator of the condition of patients with acute respiratory infections (ARI). Latest technology has many methods for detecting cough  such as analysis of direct cough sound waves  use of frequency-modulated continuous wave radar (FMCW)  convolutional peripheral nerve networks  etc.  as a reference for cough detection  but still not at the continuous measurement level in the form of cough detection intensity each time. In this study  an alternative intensity detection test will be tested using the Mel Frequency Cepstral Coefficients (MFCC) on the Edge Impulse platform to determine the accuracy of the intensity detection of ARI cough intensity. This research was carried out by creating an ISPA cough dataset  doing MFCC modeling on the Impulse design  and developing a microcontroller library. This library is uploaded to the microcontroller for a direct test of continuous cough detection with variations without pause of 5 seconds and 10 seconds from a compilation of 50 coughing sounds. The detection results accumulated a confidence level value above 50%  which was considered a cough  and the accuracy value was calculated from the ratio of the number of coughs measured. In this study  the accuracy of cough sound measurement without pauses  pause of 5 seconds  and 10 seconds was 18%  34%  and 62%  respectively.    Kata Kunci  Akurasi  Batuk  Deteksi  Edge Impulse  MFCC  Machine Learning          </note>
 <subject authority="">
  <topic>1. ALAT DETEKSI BATUK - MEL FREQUENCY CEPSTRAL COEFFICIENTS (MFCC)&#13;</topic>
 </subject>
 <classification>620.005 TEL</classification>
 <identifier type="isbn"></identifier>
 <location>
  <physicalLocation>UPT Perpustakaan UM Koleksi Bahan Pustaka Perpustakaan UM</physicalLocation>
  <shelfLocator>2</shelfLocator>
 </location>
 <slims:digitals>
  <slims:digital_item id="" url="" path="/" mimetype=""></slims:digital_item>
 </slims:digitals>
 <recordInfo>
  <recordIdentifier>-94031</recordIdentifier>
  <recordCreationDate encoding="w3cdtf">2024-10-10 00:00:00</recordCreationDate>
  <recordChangeDate encoding="w3cdtf">2024-10-10 00:00:00</recordChangeDate>
  <recordOrigin>machine generated</recordOrigin>
 </recordInfo>
</mods>
</modsCollection>